KNOW HOW: FRS—Full range FCC gasoline HDS
Usage: Technology for clean fuels production--gasoline 
Keyword:  Feed of full range FCC gasoline has high sulfur
Remarks: ✧ high sulfur removal, proper olefins removal and minimum RON loss
  ✧ high liquid yield(~100%)
  ✧ conventional hydrofining process
  ✧ mild operating conditions
  ✧ high selectivity HDS catalyst
  ✧ low hydrogen consumption(0.25~0.35%)
Aimed at
 Feed of full range FCC gasoline has high sulfur content and low olefin content:
  ✧ sulfur content in feed is between 1000-1200ppm while sulfur requirement to    effluents is lower than 500ppm;
  ✧ sulfur content in feed is around 1000ppm and olefin content is between 20-   25m% while sulfur requirement to effluents is lower than 200ppm.